Wuhan Unique Mechanical And Electrical Equipment Co., Ltd.
Home > Products > Test Equipments/n.e.s. > UN2571 Digital Earth Resistance Tester

UN2571 Digital Earth Resistance Tester

— Digital Earth Resistance Tester
Product Category: Test Equipments/n.e.s.
Sales Method: Export, Manufacture, OEM/ODM
Payment Term: T/T
Trade Term (Incoterms): FOB
Min. Order Unit Price
1 Set USD 500.00 / Set
Contact Info

Mr.John Zou

Address: China (mainland) Hubei Wuhan,Room B813, No. 61, Yejin Avenue, Qingshan District, Wuhan City, Hubei Province, China.

Product Detail

Product Attribute:

  • China (mainland) More >
  • UNIQUE
  • 07/29/2017
  • 07/31/2017

Product Content Description:

General Information:
UN2571 Digital Earth Resistance Tester is applied to test earth resistance of various equipment and conductor resistance value of low resistance. It's widely used in power electric, posts, railroad, communications, mine divisions and etc.
Features:
1. High strength aluminum alloy carrying case.
2. High anti interference ability. In order to avoid inference from power frequency, radio frequency, the device adapts phase-locked loop tracing detection synchronism method, and to be equipped with switched capacitor filter.
3. DC/AC turning technology can make DC turning to AC low frequency constant current, and easy to measure.
4. Allowed auxiliary earth resistance is changed within 0~2KΩ (RC), 0~40KΩ (RP), no influence on the test result.
5. LCD screen, can test including earth resistance, low resistance conductor resistance, soil resistivity and AC earth voltage.
6. The meter displays "1" means overflow, if the test circuit is blocked.
Specifications:
 
Working condition
 
Temperature:0ºC~+45ºC
Relative humidity: <= 85%RH
Measuring range and constant current value (RMS)
 
Resistance:0~2Ω(10mA),2~20Ω(10mA), 20~200Ω(1mA)
Voltage: AC 0~20V
Measuring precision: 0~0.2Ω<=±3%±1d
0.2Ω~200Ω<=±2%±1d
1~20V<=±3%±1d
Measuring resolution: 0.001Ω, 0.01Ω, 0.1Ω, 0.01V
Allowed auxiliary earth resistance : RC(between C1 and C2)<1.8KΩ
RP(between P1 and P2)<40KΩ Error <=±5%
Allowed earth voltage <=5V(power frequency RMS) Error<=±5%
Max. Power consumption  <=2W
Power supply: 6.8V~9V (5# Cd-Ni rechargeable battery), or connect with 220V AC source.
 