NANAO ELECTRIC WUHAN CO.,LTD.
Home > Products > Electrical Equipments/n.e.s. > NA23 Type Impulse Peak-Voltmeter

NA23 Type Impulse Peak-Voltmeter

—Complex Materials, NA23 Type Impulse Peak-Voltmeter, Impulse Voltage Peak-Voltmeter, Impulse Current Peak-Voltmeter
Product Category: Electrical Equipments/n.e.s.
Sales Method: Export, Manufacture
Payment Term: T/T, L/C
Min. Order Unit Price
1 Piece USD 5600 / Piece

Product Detail

Product Attribute:

  • China (mainland) More >
  • 550103
  • NANAO ELECTRIC
  • Complex Materials
  • Six Years
  • Automatically Testing
  • 11/22/2018
  • 11/22/2018

Additional Info.:

  • yes
  • yes
  • 999999 Sets / year
  • within 3 Days
  • Shanghai/Shenzhen/Wuhan/Guangzhou/Dalian, etc...
  • Adapt export wooden packaging standards SN-T
  • 10 kg
  • 55*40*28 (cm)

Product Content Description:

NA23 Type Impulse Peak-Voltmeter
Is used for measuring any once –impulse full waves whose first signal form's length overpass 500ns ,also measuring and storing the numerical value of the impulse peak-voltage , peak-current and other once-impulse peaks. A circuit that protects a computer system from dangerously high voltage surges. The whole design is adopted with industry standards.
NA23 Type Impulse Peak-Voltmeter
Also name
NA23 impact peak voltage table, the impact pulse peak voltmeter, the impact of the peak ammeter, the impact of the peak table, the peak pulse voltage meter, pulse peak ammeter
Introduce of NA23
NA23 Impact Peak Voltmeter for measuring and storing impulse voltage peaks, peak impulse currents, and other single pulse peaks. An internal calculation unit allows the peak of the voltage divider to be displayed directly in units of kV. Display range from 0.1kV to 16000kV.
The tester designed for use with high pressure laboratories. Use of special wiring, shielding, filtering and over-voltage protection circuit to a high degree of attenuation of electromagnetic interference.
Measuring range
The measuring cable is connected to a low voltage arm or a high current shunt of an impulse voltage divider (resistive or capacitive type device). For measuring the voltage divider (shunt), the impulse peak voltmeter will introduce a load of 2MΩ // 39pf. If necessary, for example, in the case of a resistive shock divider, a 75Ω (or 50Ω) matching resistor can be added to one of the two inputs of the table. The maximum permissible pulse voltage of the device is 1600V. Measured values ​​are displayed directly in 5 digits, in kV.
The device is different from the current commonly used impact peak table is characterized by: measuring voltage range without manual switching, and by the device automatically switch. Positive and negative polarity is automatically displayed on the display.
Main data of NA23
Pulse voltage display range: 0.1kV ~ 16000kV.
The maximum pulse voltage peak is 1600V.
Voltage measurement accuracy: error ≤ 1% ± 0.1V.
Partition ratio setting: 0.1 ~ 9999.9.
Sampling rate selection: 40M / 20M / 10M / 5M / 2.5M / 1.25M / 0.6125M / 0.30625M, corresponding time unit: 1.5us / DIV, 3us / DIV, 6us / DIV, 12us / DIV, 24us / DIV, 48us / DIV, 96us / DIV, 192us / DIV, 384us / DIV, 768us / DIV. Recommended 4/10 Waveform Select 3us / DIV, 8/20 Waveform Select 6us / DIV, 2ms Waveform Select 384us / DIV.
Or 768us / DIV.
When the 400V range is selected, the voltage scale is 50V / DIV or 25V / DIV or 10V / DIV. The instrument is set automatically. When the 20V range is selected, the voltage scale is 2.5V / DIV or 1.25V / DIV or 0.5V / DIV.
Dimensions: 490 × 130 × 300mm.
Weight: 4kg.