SCK-11 Dual Axis Inclinometer Module Description
The dual axis inclinometer module SCK-11 was designed to stationary measurements of inclinations of two orthogonal axes in relation to earth. Recommended range of measured angles maintains from -70 to +70 deg. Due storing of new scaling values to internal registers it is possible to change measurement unit and resolution to any other linear. Build in offset registers allows user to measure relative angles and self zeroing after mounting. In addition to two registers containing information about SCK-11 installation plane angle relative to the earth (two angles with the offset function), threre are available additional two records containing information on the accelerations in the same axes, what makes measurement of transducer movement more precision.

SCK-11 Dual Axis Inclinometer Module Features
- Two measurement channels,
- Build-in temperature sensor,
- Resistance for mechanical damages,
- Aluminium housing.

SCK-11 Dual Axis Inclinometer Module Applications
Possible application fields:
- Industry and farming
- Position control equipement
- Measurement systems of lifts etc.


SCK-11 Dual Axis Inclinometer Module Technical data

Power supply 10 - 36V DC
Current consumption during operation - typically 12 mA @ 24V DC
during Modbus transmission - up to 60 mA
Angle detector MEMS
Measurement channels (axes) 2
Measurement range ±70 deg. in relation to earth
Measurement unit any (factory scaled to degrees)
Measurement resolution from 0,001 to 1, user configured
Measurement accuracy ±30 deg. (better than 0,2%; max. error 0,05 deg. @25°C)
±70 deg. (better than 0,5%; max. error 0,2 deg. @25°C)
Nonlinearity ±0,1%
Recommended maximum gravity measurement range ±1,5G (1G = gravitational acceleration of earth)
Acceleration unit and resolution 0,001 G
Communication interface RS 485, 8N1 / Modbus RTU, not separated, baud rate
1200 bit/s ÷ 115200 bit/s
Compensation range -40°C ÷ 85°C
Operation temperature recommended -30°C to +60°C; 
max. -40°C to +85°C
Vibration frequency higher than 10Hz
Protection level IP 67
Case type wall mounted
Case material aluminium
Mounting to wall, 2 M3 bolts
Dimensions without glands 75 x 80 x 57 mm, 
with glands 100 x 80 x 57 mm
Weight 350 g