Home > Trade Leads > Electrical Components & Equipments > Sensors & Transducers > Gas Sensors > Sell > 3SP_NO2_5F C 15X15 NO2 Sensor 0-5 Ppm FC Package 110-508

3SP_NO2_5F C 15X15 NO2 Sensor 0-5 Ppm FC Package 110-508

Post Date:

2019/01/10 17:21:51

Expired Date:

2019/04/10 23:59:59

Trade Leads Category:

Gas Sensors

Company Info

Shenzhen Week Technology Ltd.
Contact Person: Yan Zhang
Address: 16 Floor, Building #3, Zhongke Mansion, Gaoxin South 1St Rd, Hi-Tech Park, Nanshan
City: SHENZHEN
State/Province: GUANGDONG
Country/Region: China (mainland)
Zip/Post Code: 518067


Details

3SP_NO2_5F C NO2 Sensor DESCRIPTION
SPEC’s printed sensors offer the performance of the best quality electrochemical sensors at a fraction of the price. SPEC’s printed sensors are also ultra-thin, offering easy integration into wireless, portable, and networked solutions. These sensors are ideal for health, environmental, industrial and residential monitoring, because of their high performance, low cost and small size. 

3SP_NO2_5F C NO2 Sensor BENEFITS
• NEW Onboard Filter Removes Ozone!!!
• NEW More Stable with T & RH!!!
• Small Size with Low Profile (20x20x3 mm)
• Long Life (10 years expected life)
• Fast Response (< 15 seconds)
• Low Power Consumption
• ROHS Compliant

3SP_NO2_5F C NO2 Sensor APPLICATIONS
• Air Quality Monitoring
• Industrial Safety
• Air Purification Control

3SP_NO2_5F C NO2 Sensor SPECIFICATIONS

Measurement Range 0 to 5 ppm
Resolution < 20 ppb (instrumentation dependent)
Repeatability < +/- 3 % of reading
Response Time T90 < 300 ( 200 seconds typical)
Sensitivity @ -25 mV bias -30 +/- 15 nA/ppm
Expected Operating Life > 5 years (10 years @ 23+/-3C; 40+/-10% RH)
Operating Temperature Range -40 to 50 C (-20 to 40 C recommended)
Operating Humidity Range - non-condensing 0 to >95% RH (15 to 95% continuous)
Power Consumption 10 to 50 uW (circuit & ambient NO2 dependent)

3SP_NO2_5F C NO2 Sensor CROSS SENSITIVITY
Most chemical sensors exhibit some cross-sensitivity to other gases. The following table lists the relative response of common potential interfering gases, and the concentration at which the data was gathered. Additional data will be made available as it is collected. Contact SPEC sensors for additional information.

Gas ppm Typical Response as ppm NO2
Carbon Monoxide 100 <0.02
Chlorine 10 <0.5
Ethanol 100 <1
Hydrogen Sulfide 5 <0.02
Nitric Oxide (NO) 5 <0.1
Nitrogen Dioxide 5 <5
Ozone  1 <0.1
Sulfur Dioxide 5 <0.02