Home > Trade Leads > Security & Protection > Alarms & Sensors > Alarms & Sensors/n.e.s. > Sell > 15J(S)/30J(D)-P1 Gas Sensor Transmitter

15J(S)/30J(D)-P1 Gas Sensor Transmitter

Post Date:

2018/11/13 17:28:21

Expired Date:

2019/02/11 23:59:59

Trade Leads Category:

Alarms & Sensors/n.e.s.

Company Info

Shenzhen Week Technology Ltd.
Contact Person: Yan Zhang
Address: 16 Floor, Building #3, Zhongke Mansion, Gaoxin South 1St Rd, Hi-Tech Park, Nanshan
City: SHENZHEN
State/Province: GUANGDONG
Country/Region: China (mainland)
Zip/Post Code: 518067


Details

GAS SENSOR TRANSMITTER
Safe Area Detector Head / Junction Box Assembly

15J(S)/30J(D)-P1 Gas Sensor Transmitter Description
The 30J enclosure has been designed to allow quick and easy access to its interior by adjustment of two allen screws, this factor is a major consideration when large system service and calibrations are being carried out. 

The detector is robust and weather-proof with improved response times due to the four mounting spacers allowing increased air movement around the detector these spacers also improve the mounting of the unit particularly on circular pillars typically found in carparks. Standard 4~20mA signalling with CANbus address enables the sensors to be networked via the GDS Combi control system or customer preferred monitoring system.

15J(S)/30J(D)-P1 Gas Sensor Transmitter Features
• Flexible output options
• CANbus, 4~20mA output
• Addressable or stand alone
• Hyper terminal communications rs232 line data and set up with 232 adapter
• Data logging
• Optional alarm relays
• Robust and weather-proof

15J(S)/30J(D)-P1 Gas Sensor Transmitter Specifications

Power Supply 15 to 30vDC 24v nominal
Outputs 3 wire - 4~20mA
4 wire - CANbus
Relays (optional)
Low alarm S.P.C.O
High alarm S.P.C.O
Fault alarm S.P.C.O / overrange
Rating 0.5A @30vDC
Inhibit option during servicing
Logging Addressable sensors only
Intervals - variable time
Roll over/stop
Storage - 2,880 readings
Temperature -15˚C to 55˚C
Humidity Pellistor-catalytic: 0 - 99% RH non condensing
Electrochemical: 5 - 95% RH non condensing
Infrared: 0 - 95% RH non condensing
   
DETECTOR HEAD Type - P1 Safe area use
Ingress Protection IP63, + Universal fitting IP65
Material ABS - black
Sensor Inserts - 4 series Electrochemical
Infra Red
Semiconductor
Pellistor - Catalytic
PID
Accessories - Optional Collector Cone + Universal Fitting
Universal Fitting (test gas applicator/spray deflector)
Flow Block
Duct Mount Kit
Detector Head Weather Shield
   
JUNCTION BOX Type - 15/30J safe area use only
15J - shallow box (S)
30J - deep box (D)
Ingress Protection IP64
Material ABS Flame retardent FR40
Lid Screws M4SS
Finish Signal White RAL 9003
Weight 380gms
Entries Rear 5-20mm knock outs
Sides, Top, Bottom - not specified
Mounting Standoffs - M4 or No 8 screws
Drill at (C) when standoffs removed
Conduit box - drill at (A) 4.5mm
Surface mount box - drill at (B) 4.5mm
EU Design No. 01359723-0001

Related Searches on ttnet.net: