Home > Trade Leads > Electrical Components & Equipments > Sensors & Transducers > Gas Sensors > Sell > KSIM 1260 Sulfur Hexafluoride (SF6) Gas Sensor

KSIM 1260 Sulfur Hexafluoride (SF6) Gas Sensor

Post Date:

2018/11/05 15:05:41

Expired Date:

2019/02/03 23:59:59

Trade Leads Category:

Gas Sensors

Company Info

Shenzhen Week Technology Ltd.
Contact Person: Yan Zhang
Address: 16 Floor, Building #3, Zhongke Mansion, Gaoxin South 1St Rd, Hi-Tech Park, Nanshan
City: SHENZHEN
State/Province: GUANGDONG
Country/Region: China (mainland)
Zip/Post Code: 518067


Details

Gas sensor KSIM 1260 for detection of Sulfur Hexafluoride SF6
 
Mode of operation
The KSIM 1260 is a high quality infra red Sulfur Hexafluoride gas detector designed to operate with KIMESSA or third party control panels.
 
The infra red sensor technology is diffusion based and Sulfur Hexafluoride specific, housed in a robust metallic enclosure and designed for one-person calibration.
 
The versatile KSIM 1260 outputs allow for user selection of 0-20mA, 4-20mA, 0-10Vdc and digital BUS. The BUS option is used in conjunction with the addressable KIMESSA CANline-32-channel gas monitor panel, incorporating data logging and multi-optional programming capability. The SF6-detector is available with a linearised measuring range from 0~1000 ppm (0.1 Vol. %) up to 0~5.0 Vol. % and its output signal is temperature compensated from -30'C to +70'C.
 
A novel feature on the KSIM 1260 facilitates direct measurement of the gas level via a 3.5mm jack connection, enhancing the overall flexibility of the SF 6 sensor.
 
The KSIM 1260 is also designed for use with a hand held optical calibration tool called the CRC–Calibration Remote Control, permitting calibration of remote SF 6 sensors.

 

KSIM 1260 Sulfur Hexafluoride SF6 Sensor Technical specifications

Measuring range 0…1000 ppm/0…5 Vol. % (others on request)
Response time t90 < 90 seconds
Operating temperature -30 °C ... +70 °C
Start up after reconditioning maximum 1 h
Pressure range atmospheric ± 10%
Air humidity 5...95%
Location sensitivity none
Life-span at 20 °C depends on the application
Protection class IP 54
Weight 550 gr
Current consumption maximum 60 mA
Output signal analogue (selectable with jumper)  4...20 mA/ 0...20mA/ 0...10 VDC/ 2...10 VDC 
Cable analogue 3-core cable, shielded, 3x1.00m
Output signal BUS (digital) CAN-Bus
Cable BUS (digital) 4-core cable, shielded, 4x1.00m2
Supply voltage 16.0...30.0 VDC


KSIM 1260 Sulfur Hexafluoride SF6 Sensor Cross sensitivity to other gases

Test gas concentration of the test gas display on the SF6-Detector
Ammonia NH3 100 ppm ...
Chlorine Cl2 50 ppm ...
Carbon Dioxide CO2 5000 ppm ...
Carbon Monoxide CO 250 ppm ...
Propane C3H8 5000 ppm ...
Sulphur Dioxide SO2 100 ppm ...
Hydrogen Sulphide H2S 50 ppm ...
Nitrogen Dioxide NO2 20 ppm ...
Nitric Oxide NO 48 ppm ...
Hydrogen H2 90 ppm ...