 FSM-BP-01Combustible gas sensor Module Features:
* PWM, USART digital output proportional to gas concentration
* Maintain Free
* Compact size, low cost
* Meets RoHS requirement
 
FSM-BP-01Combustible Gas sensor Module Applications:
* Detect flammable gas leakage
* Flammable gas leakage Detector
* Industrial detector
 
FSM-BP-01 is pre-calibrated module for LPG gas alarm which applies TGS2610-D00 sensor together, it features durability and stability. The module  outputs  PWM  signal  which  is proportional to LPG gas concentration (The module has a memory which is stored with factory calibration data), also is capable of detecting sensor wire breakage and short. The module can operate at wide temperature from -10~70°C. 
 
Furthermore, the unit is less sensitivity to VOCs gas, it immunes poison by silicon compounds, it suits to work at rugged environment.
 
FSM-BP-01Combustible Gas Sensor Module Specification:

Product name

Combustible gas sensor module

Model No.

FSM-BP-01

Gas sensor

TGS2610-D00(Semiconductor)

Detection range

0 ~ 4,000ppm H2 

(also can detect methane, iso-butane, and propane)

Error

±300ppm

Output voltage (Vconc)

 PWM(2KHz)

Trouble

Trouble:H, Normal:L

Response time (T90)

≦30S

Operating conditions

-10˚C ~+70˚C, 20~95%RH(No condensing)

Storage conditions

-10˚C ~+80˚C, 20~95%RH

Input voltage (VIN)

5.0±0.2V DC

Power consumption

≦1.5W

Weight

15g or less

Dimensions

26*27mm

Standard test conditions

Ambient conditions

20±2˚C, 65±5%RH

Circuit conditions

 5.0±0.2V

Conditioning period prior to test

≧10 minutes


 